TEMPERATURE CYCLE

Temperature cycle capable of meeting various test condition, please refer to table listed below for detail test condition.

 
a. Mil-Std-883, Method 1010 Specifications:
- Total Transfer Time <= 1 minute
- Total Dwell Time >= 10 minutes
- Specified Temp reached in <= 15 minutes 
 
Mil-Std-883 Method 1010 Temp Cycle Test Conditions

Condition
Low Temp
High Temp
A
 -55 (+0/-10) deg C
85 (+10,-0) deg C
B
-55 (+0/-10) deg C
125 (+15,-0) deg C
C
 -65 (+0/-10) deg C
150 (+15,-0) deg C

               
b. JEDEC JESD22-A104 Specifications:
- Total Transfer Time <= 1 minute
- Total Dwell Time >= 10 minutes
- Specified Temp reached in <= 15 minutes
                        
JEDEC JESD22-A104 Specifications:

Condition
Low Temp
High Temp
A
 -55 (+0/-10) deg C
85 (+10,-0) deg C
B
-55 (+0/-10) deg C
125 (+10,-0) deg C
C
 -65 (+0/-10) deg C
150 (+10,-0) deg C
G
-40 (+0/-10) deg C
125 (+10,-0) deg C
H
-55 (+0/-10) deg C
150 (+10,-0) deg C